3.3 Preparations for Use
Take electrostatic prevention measures. Note that some carpets generate static electricity easily
and can cause the PRIMEPOWER200 Rackmount (4U) Server to malfunction.
When moving the PRIMEPOWER200 Rackmount (4U) Server, do not pull on the front cover.
Otherwise, the Server may be damaged.
3.3.2
Installation specifications
Table 3.2 and Table 3.3 show the installation specifications for the PRIMEPOWER200 Rackmount (4U) Server.
Table 3.2
Installation Specifications of the PRIMEPOWER200 Rackmount (4U) Server (1/2)
Item
Specification
Weight
50 kg (110.38 lb.) (max.)
(*1)
Power Supply
Voltage
Frequency
50/60 Hz (+2 ~ -4%)
Max. Current
6.1 A (100V)
Leak Current
Frame Resistance
Temperature
Operating
Non-Operating
Humidity
Operating
20 ~ 80% RH (non-condensing)
Non-Operating
8 ~ 80% RH (non-condensing)
Vibration
Operating
0.2 G
Non-Operating
0.4 G
Noise
50 db(A) (*3)
Form Factor
Rackmount (4U)
2.6 A (240V)
Single phase
AC100
~ 120V
(
±
10%)
Single phase
AC200
~ 240V
(
±
10%)
²
3.5 mA
²
100
Ω
5 ~ 35
û
C (+41 ~ +95 F) (*2)
0 ~ 50
û
C (+32 ~ +122 F)
*1:
Include Rack Rail weight.
*2:
If the ambient temperature exceeds 35 deg. C (95 deg. F) during operation, a warning message is
displayed. Take steps to rectify the problem immediately.
*3:
The indicated noise is the mean value of measurements obtained when the server unit is installed in
an 1800mm (71-inch) rack server in a low-noise anechoic chamber. The actual noise measured at
the installation site may be greater than the indicated value due to background noise and echoes.
33
Summary of Contents for Primepower200
Page 1: ...P321 E122 04EN PRIMEPOWER PRIMEPOWER200 PRIMEPOWER400 PRIMEPOWER600 ...
Page 2: ......
Page 12: ......
Page 116: ......
Page 142: ......
Page 192: ......
Page 254: ......
Page 255: ...12 RCI Commands CONTENTS 12 1 Overview 228 12 2 RCI Commands 228 227 ...
Page 258: ......
Page 266: ......
Page 267: ...14 Glossary CONTENTS 14 1 Glossary 240 239 ...
Page 272: ......