Table
3-11
Problems
resolved
in
XCP
2220
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
140314-002
x
In
case
XCP
2210
is
applied
to
a
SPARC
M10-4S,
that
is
attached
to
a
crossbar
box
(XBBOX),
if
the
crossbar
cable
is
degraded
due
to
some
problems,
the
following
symptom
may
occur
while
the
system
is
running.
-
If
a
failure
occurs
in
the
crossbar
unit
(XBU)
of
the
crossbar
box
(XBBOX),
it
may
not
be
detected
and
the
physical
partition
may
hang
up.
Failure
of
crossbar
cable
can
be
confirmed
by
any
of
the
following
error
logs:
FRU:
/BB#n/XBU#x/CBL#y,/
BB#n/XBU#x,/XBBOX#m/XBU#x
Msg:
XB-XB
interface
fatal
bus
protocol
error
Or,
FRU:
/BB#n/XBU#x/CBL#y,/
BB#n/XBU#x,/XBBOX#m/XBU#x
Msg:
XB-XB
interface
timeout
error
Or,
FRU:
/BB#n/XBU#x/CBL#y,/
BB#n/XBU#x,/XBBOX#m/XBU#x
Msg:
XB-XB
interface
link-up
error
If
a
problem
of
any
crossbar
cable
has
occurred,
stop
all
PPARs
immediately
and
replace
the
crossbar
cable.
[How
to
restore]
1.
Stop
all
PPARs.
If
any
of
them
cannot
be
stopped
normally,
stop
it
forcibly.
2.
Replace
the
degraded
crossbar
cable.
3.
Diagnose
the
hardware
with
the
"testsb
-a"
command
and
confirm
whether
there
is
any
failure
of
the
XBU
of
XBBOX.
4.
If
there
is
any
failure
in
the
XBU,
replace
it.
RTIF2-
140402-002
x
x
x
In
the
search
function
for
each
log
in
the
[XSCF]
-
[Logs]
menu
on
the
XSCF
Web,
if
you
click
the
[Search]
button
with
both
[Start]
and
[End]
times
set
to
execute
a
search,
a
message
indicating
an
error
in
the
specified
period
may
be
output
and
it
may
not
be
possible
to
execute
the
search.
Use
the
showlogs(8)
command
of
the
XSCF
shell.
RTIF2-
140407-002
x
x
x
In
a
system
configuration
with
a
connected
PCI
expansion
unit,
you
may
update
XCP
firmware
or
reset
XSCF
with
the
physical
partition
(PPAR)
powered
on.
In
this
case,
the
PCI
expansion
unit
information
is
not
output
to
the
result
of
executing
the
ioxadm(8)
command
or
showhardconf(8)
command.
Or,
the
PCI
expansion
unit
can
no
longer
be
controlled
with
the
ioxadm(8)
command.
There
is
no
effective
workaround.
[How
to
restore]
Execute
either
of
the
following.
-
Power
off
the
PPAR
and
then
power
it
on
again.
-
Use
PCI
hot
plug
(PHP)
to
remove
the
link
card
from
the
system
and
reinstall
it.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
100
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...