Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
140410-005
x
x
x
If
a
hardware
error
is
detected
immediately
after
powering
off
or
restarting
the
physical
partition
(PPAR),
the
PPAR
power
off
or
restart
process
may
be
stopped,
and
may
not
be
completed.
To
check
whether
this
phenomenon
has
occurred,
power
off
or
restart
the
PPAR
and
then
execute
the
showpparprogress
(8)
command.
If
the
PPAR
remains
in
the
power
on
state
and
the
power
off
process
has
not
completed
after
at
least
one
minute
has
passed,
this
phenomenon
has
occurred.
[Example
of
unsuccessful
power
off]
XSCF>
showpparprogress
-p
0
This
PPAR
is
powered
on.
Normally,
when
the
PPAR
power
off
completes,
the
power
off
sequence
and
PPAR
state
are
as
follows.
[Example
of
successful
power
off]
XSCF>
showpparprogress
-p
0
PPAR
Power
Off
PPAR#0
[1/3]
CPU
Stop
PPAR#0
[2/3]
PSU
Off
PPAR#0
[3/3]
The
sequence
of
power
control
is
completed.
There
is
no
effective
workaround.
[How
to
restore]
If
the
PPAR
power
supply
remains
in
the
power-on
state
30
minutes
after
executing
the
showpparprogress(8)
command,
turn
off
the
input
power
to
all
chassis
and
then
turn
it
on
again
(AC-OFF/ON).
RTIF2-
140410-008
x
Even
if
the
XSCF
DUAL
control
cable
is
reconnected
after
the
system
input
power
has
been
turned
on
with
this
cable
disconnected,
data
synchronization
between
the
master
chassis
and
standby
chassis
cannot
be
secured.
Continuous
system
operation
is
possible.
However,
after
switching
the
master
and
standby
XSCFs,
normal
system
operation
is
not
guaranteed.
This
is
because
information
in
the
old
master
XSCF
is
not
reflected
in
the
new
XSCF.
Before
turning
on
the
input
power,
confirm
that
the
XSCF
DUAL
control
cable
is
correctly
inserted.
[How
to
restore]
Execute
the
rebootxscf
-a
command
to
reset
all
XSCFs.
RTIF2-
140410-009
x
If
the
input
power
to
the
standby
or
slave
chassis
is
turned
off,
a
"Board
control
error
(MBC
link
error)"
error
log
may
be
registered.
There
is
no
effective
workaround.
Ignore
this
error
log.
RTIF2-
140507-003
x
After
adding
or
removing
a
system
board
with
the
dynamic
reconfiguration
of
physical
partitions
(PPAR),
if
the
PPAR
is
powered
off,
the
output
of
the
There
is
no
effective
workaround.
[How
to
Restore]
After
the
"PPAR-ID
x:
Reset"
message
is
output
to
the
event
log,
re-execute
the
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
66
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...