Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
140606-001
x
x
x
Suppose
that
a
cluster
system
is
built
to
fulfill
the
following
condition:
It
is
composed
of
multiple
SPARC
M10
Systems
chassis
each
of
which
includes
10
or
more
guest
domains
(10
or
more
cluster
nodes)
running
in
one
physical
partition
(PPAR).
Moreover,
PRIMECLUSTER
software
is
installed
on
each
of
these
guest
domains.
Alternatively,
the
cluster
system
is
composed
of
multiple
PPARs
within
the
SPARC
M10
Systems
chassis.
If
you
execute
the
poweroff
-f
command
on
one
PPAR
to
forcibly
turn
off
the
power
to
that
PPAR,
the
XSCF
may
slow
down,
panic,
and
then
reset.
Confirm
that
less
than
10
cluster
nodes
are
included
in
one
PPAR
that
exists
on
an
instance
of
SPARC
M10-1,
SPARC
M10-4,
or
SPARC
M10-4S.
[How
to
restore]
The
system
will
be
available
as
is
because
the
poweroff(8)
command
continues
being
processed
after
the
XSCF
has
panicked
and
reset.
RTIF2-
140606-004
x
Suppose
that
you
execute
the
addboard
(8)
and
reset
por
commands
to
add
a
system
board
(PSB)
to
a
physical
partition
(PPAR)
that
fulfills
both
of
the
conditions
below.
You
may
see
an
error
message
"No
analytical
target"
repeatedly.
Also,
Oracle
Solaris
running
on
this
PPAR
may
hang
up.
-
The
SPARC
M10-4S
(including
a
crossbar
box)
has
a
building-block
configuration.
-
Power
is
supplied
only
to
a
PPAR
made
up
of
one
PSB.
To
add
a
PSB
to
a
PPAR
that
fulfills
the
conditions
shown
on
the
left,
use
one
of
the
following
methods:
-
Turn
off
the
power
to
the
PPAR,
and
then
execute
the
addboard(8)
command
to
add
a
PSB.
-
After
executing
the
addboard(8)
command
to
add
a
PSB,
turn
off
the
power
to
the
PPAR,
turn
it
on
again,
and
then
rebuild
the
PPAR.
-
Using
the
DR
function,
execute
the
addboard(8)
command
to
add
a
PSB.
[How
to
restore]
-
If
the
error
message
"No
analytical
target"
is
not
displayed
Execute
the
poweroff(8)
command
to
turn
off
the
power
to
the
PPAR,
and
then
execute
the
poweron(8)
command
to
turn
on
the
power
to
the
PPAR.
-
If
the
error
message
"No
analytical
target"
is
displayed
Execute
the
poweroff
-f
command
to
forcibly
turn
off
the
power
to
the
PPAR
and
then
execute
the
poweron(8)
command
to
turn
on
the
power
to
the
PPAR.
RTIF2-
140606-008
x
Suppose
that
you
are
attempting
the
following:
Adding
a
system
board
(PSB)
with
the
addboard
-c
configure
command
using
dynamic
reconfiguration
of
physical
partitions
(PPARs)
or
disconnecting
a
PSB
using
the
deleteboard
-c
unassign
or
deleteboard
-c
disconnect
command.
If
any
of
the
If
there
is
a
standby
XSCF
that
fulfills
the
condition
shown
on
the
left,
execute
the
addboard(8)
or
deleteboard(8)
command
after
the
standby
XSCF
has
restarted.
Check
whether
the
XSCF
has
restarted,
by
executing
the
showhardconf(8)
command
to
confirm
that
the
[Status]
of
the
SPARC
M10-4S
chassis
(BB#xx)
that
Chapter
3
Information
on
Software
73
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...