Table
3-21
Problems
resolved
in
versions
prior
to
XCP
2050
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
121219-012
x
When
a
SPARC
M10-4S
chassis
is
replaced
using
the
replacefru(8)
command,
replacement
of
the
SPARC
M10-4S
chassis
may
fail
with
"internal
error"
displayed.
Use
the
following
procedure
to
replace
a
SPARC
M10-4S
chassis
by
using
the
replacefru(8)
command.
1.
Enter
"r"
to
replace
the
chassis
in
response
to
the
message
"Do
you
want
to
continue?[r:replace|c:cancel]"
which
is
displayed
after
the
replacefru(8)
command
is
executed.
2.
Replace
the
SPARC
M10-4S
chassis
and
wait
for
about
15
minutes
after
the
input
power
of
the
chassis
is
turned
on.
3.
Execute
the
showlogs
event
command
to
display
an
event
log.
4.
Continue
the
replacement
using
either
of
the
following
methods.
-
If
the
event
log
displays
"XSCF
update
is
started"
Wait
until
the
"XCP
update
has
been
completed"
log
is
registered.
When
"XCP
update
has
been
completed"
is
displayed,
enter
"f"
in
response
to
"Please
select[f:finish]"
and
then
continue
the
replacement
by
following
the
instructions
displayed
on
the
screen.
-
If
the
event
log
does
not
display
"XSCF
update
is
started"
Enter
"f"
in
response
to
"Please
select[f:finish]"
and
then
continue
the
replacement
according
to
the
instructions
on
the
screen.
RTIF2-
121219-013
x
When
a
SPARC
M10-4S
chassis
finds
an
error
indicating
that
the
XSCF
cannot
be
started,
not
only
an
error
log
for
the
SPARC
M10-4S
chassis
where
the
error
occurred
but
also
an
error
log
regarding
a
cable
connection
error
in
a
chassis
that
does
not
exist
may
be
registered.
Ignore
the
error
log
regarding
a
cable
connection
error
registered
for
a
SPARC
M10-4S
chassis
that
does
not
exist.
RTIF2-
121219-014
x
When
cold
replacement
is
performed
(replacement
performed
while
the
input
power
is
off)
due
to
an
error
with
BB#00,
the
setting
information
for
the
XSCF
is
deleted.
To
replace
a
SPARC
M10-4S
chassis
due
to
an
error
in
BB#00,
use
the
replacefru(8)
command.
RTIF2-
121219-015
x
When
a
SPARC
M10-4S
chassis
is
removed
with
the
initbb(8)
command,
the
information
on
the
removed
chassis
remains
without
being
completely
deleted.
To
remove
a
SPARC
M10-4S
chassis,
perform
the
cold
removal
(the
chassis
is
removed
by
turning
off
the
input
power).
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
150
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...