Table
7-2
Problems
resolved
in
version
1180
of
the
PCI
expansion
unit
firmware
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
140715-001
x
x
x
In
a
PCI
expansion
unit,
if
the
power
supply
unit
(PSU)
has
a
redundant
configuration
and
the
power
cable
connected
to
one
of
the
power
supply
units
is
pulled
out,
a
PSU
error
may
be
erroneously
detected,
and
the
PCI
expansion
unit
chassis
Check
LED
(amber)
may
go
on.
At
this
time,
executing
the
showlogs
error
command
outputs
the
"Msg:
PSU
failed"
log.
There
is
no
effective
workaround.
[How
to
restore]
Use
either
of
the
following
procedures.
-
How
to
restore
1
Turn
off
the
power
to
the
SPARC
M10
chassis
connected
to
the
PCI
expansion
unit.
Then
disconnect
both
PCI
expansion
unit
power
cables
(AC
OFF).
Then,
wait
for
30
seconds
to
reconnect
the
cables
(AC
ON).
-
How
to
restore
2
Perform
pseudo
active
replacement
of
the
PSU
in
which
the
error
has
been
detected
(temporarily
remove
the
PSU
and
then
reinstall
it).
When
performing
pseudo
replacement
of
the
PSU,
use
the
ioxadm(8)
command.
Note
that
the
fieldeng
privilege
is
required
to
execute
the
ioxadm(8)
command.
RTIF2-
141111-003
x
x
x
In
a
PCI
expansion
unit,
a
power
supply
unit
(PSU)
failure
is
erroneously
detected
if
you
perform
the
following
operations
in
the
condition
that
a
power
cable
connected
to
either
of
PSUs
in
a
redundant
configuration
is
pulled
out.
-
Power-on
of
a
physical
partition
(PPAR)
-
Mount
a
PCI
expansion
unit
in
PCI
hot
plug
(PHP)
Also,
Check
LED
(amber)
of
the
PCI
expansion
unit
chassis
may
go
on.
You
can
confirm
this
phenomenon
with
the
showlogs
error
-v
command.
If
the
result
of
the
showlogs
error
-v
command
shows
"Msg:PSU
failed",
and
the
fifth
(x08)
bit
from
left
of
the
second
byte
of
the
forth
line
of
Diagnostic
Code
shows
1
(any
of
*8,
*9,
*a,
*b,
*c,
*d,
*e,
*f),
it
corresponds
to
this
failure.
[Error
message
example]
If
the
left
of
the
second
byte
of
the
forth
line
of
Diagnostic
Code
shows
"49":
XSCF>
showlogs
error
-v
Date:
Nov
06
17:10:14
JST
2014
Code:
80000408-
There
is
no
effective
workaround.
[How
to
restore]
-
How
to
restore
1
Power
off
the
SPARC
M10
chassis
to
which
the
PCI
expansion
unit
is
connected,
then
pull
out
both
power
cables
(AC
OFF)
of
the
PCI
expansion
unit.
Wait
for
30
seconds,
then
connect
both
power
cables
(AC
ON).
-
How
to
restore
2
Perform
pseudo
active
replacement
of
the
PSU
in
which
the
error
is
erroneously
detected
(temporarily
remove
the
PSU
and
then
reinstall
it).
When
performing
pseudo
active
replacement
of
the
PSU,
use
the
ioxadm(8)
command.
Note
that
the
fieldeng
privilege
is
required
to
execute
the
ioxadm(8)
command.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
190
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...