Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
the
error
log
"Code:80000000-
XXXXXX0000ff0000ffxxxxxxxxxx000000
00000000"
output
by
the
showlogs
error
command.
-
If
the
value
of
XXXXXX
is
"002400"
Type:
A:
PSU
for
SPARC64
X
-
If
the
value
of
XXXXXX
is
"002401"
Type:
B:
PSU
for
SPARC64
X+
RTIF2-
140616-002
x
x
x
When
the
procedure
below
is
executed,
the
error
message
"An
internal
error
has
occurred.
Please
contact
your
system
administrator."
is
displayed
at
execution
of
the
prtfru(8)
command
and
the
command
abnormally
terminates.
1.
Turn
on
the
input
power
and
then
execute
the
rebootxscf(8)
or
switchscf(8)
command
to
start
or
reset
the
XSCF.
2.
Execute
the
snapshot(8)
command.
3.
Execute
the
prtfru(8)
command.
After
starting
or
resetting
the
XSCF,
execute
the
prtfru(8)
command
before
executing
the
snapshot(8)
command.
[How
to
restore]
Execute
the
rebootxscf
-a
command
to
reset
all
XSCFs.
RTIF2-
140616-004
x
When
you
execute
the
switchscf(8)
command,
XSCF
master/standby
switching
may
take
time.
As
a
result,
the
following
error
may
occur:
Master
switch
synchronization
timeout.
There
is
no
effective
workaround.
If
the
current
master
XSCF
differs
from
what
you
intended,
re-execute
the
switchscf(8)
command.
RTIF2-
140616-005
x
If
you
turn
off
the
input
power
of
the
master
XSCF
(AC
OFF)
and
then
turn
it
on
again
(AC
ON)
when
the
power
to
the
physical
partition
(PPAR)
is
off,
error
handling
may
fail
due
to
the
temporary
absence
of
the
master
XSCF.
In
addition,
the
PPAR
may
remain
abnormal
so
that
you
may
be
unable
to
power
on
the
PPAR
again.
You
can
determine
the
occurrence
of
this
phenomenon
by
executing
the
showboards(8)
command.
If
the
value
of
"Pwr
Conn
Conf"
displayed
as
the
master
XSCF
PSB
status
is
"n
y
n,"
this
phenomenon
has
occurred.
[Example]
If
the
master
XSCF
is
BB#00:
XSCF>
showboards
-a
PSB
PPAR-ID
Assignment
Pwr
Conn
Conf
Test
Fault
---
-------
-----------
----
----
----
-------
--------
00-0
00(00)
Assigned
n
y
n
Passed
Normal
01-0
01(00)
Assigned
y
y
n
Passed
Normal
There
is
no
effective
workaround.
[How
to
restore]
Turn
off
the
input
power
to
all
SPARC
M10-4S
chassis
that
make
up
the
system
and
then
turn
it
on
again.
Chapter
3
Information
on
Software
75
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...