Table
3-16
Problems
resolved
in
XCP
2080
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
121219-011
x
The
power
of
a
physical
partition
(PPAR)
may
not
be
disconnected
if
deleteboard
-c
unassign
is
executed
to
the
system
board
that
belongs
to
the
PPAR
while
the
power
of
the
PPAR
is
being
disconnected
using
the
poweroff(8)
command.
After
executing
the
poweroff(8)
command,
confirm
that
the
status
field
of
the
relevant
PPAR
shows
Powered
Off
by
using
the
showpcl(8)
command.
Then,
execute
the
deleteboard(8)
command.
RTIF2-
130305-018
x
An
internal
error
may
occur
when
performing
"Diagnostic
tests"
when
selecting
"BB"
with
the
replacefru(8)
command
or
executing
the
testsb(8)
command.
If
you
check
the
error
log
at
this
time,
you
can
see
that
"no
PSB
available
in
PPAR"
was
registered
in
"PPAR#30"
when
the
internal
error
occurred.
An
error
occurred
in
the
applicable
SPARC
M10-4S
and
the
system
board
(PSB)
is
in
an
unavailable
state.
Check
the
error
log
and
replace
the
SPARC
M10-4S.
RTIF2-
130305-019
x
x
x
Diagnosis
continues
even
when
an
error
occurred
on
the
testsb(8)
command
and
timeout
occurs
after
a
two-hour
wait.
Execute
the
showboards(8)
command
in
another
session
while
executing
the
testsb(8)
command
to
check
the
status
of
PSB
to
be
diagnosed.
An
operation
will
fail
if
"Test"
is
set
to
other
than
"Testing"
and
"Pwr"
is
set
to
"n".
In
this
case,
cancel
the
testsb(8)
command
by
pressing
[Ctrl]
+
[C].
RTIF2-
130307-001
x
If
any
SPARC
M10-4S
that
is
specified
with
the
diagxbu(8)
command
is
not
implemented,
the
message
"PSB#xx-0
is
not
installed."
showing
the
PSB
No.
that
represents
the
unimplemented
SPARC
M10-4S
should
appear.
However,
the
PSB
No.
of
the
SPARC
M10-4S
which
actually
has
been
implemented
may
be
erroneously
output.
There
is
no
effective
workaround.
Execute
the
showhardconf(8)
command
to
check
the
status
of
the
SPARC
M10-4S
to
which
the
corresponding
PSB
No.
is
assigned.
The
SPARC
M10-4S
which
has
not
been
implemented
is
not
displayed
with
the
showhardconf(8)
command.
When
the
corresponding
SPARC
M10-4S
is
displayed,
read
the
PSB
No.
in
the
message
"PSB#xx-0
is
not
installed."
as
that
of
the
unimplemented
SPARC
M10-4S
that
was
specified
when
this
command
was
executed.
RTIF2-
131001-001
x
If
the
SPARC
M10-4S
or
the
crossbar
box
is
disconnected
with
the
initbb(8)
command,
and
then
all
chassis
are
turned
off
and
then
on
again
with
the
XSCF
BB
control
cable
left
connected,
the
chassis
disconnected
with
the
initbb(8)
command
will
become
the
master
chassis,
and
the
XSCF
settings
will
be
initialized
to
the
factory
defaults.
Be
sure
to
follow
the
procedure
below
when
disconnecting
the
SPARC
M10-4S
and
the
crossbar
box.
1.
Execute
the
initbb(8)
command
to
stop
the
target
chassis.
2.
Turn
off
the
stopped
chassis
first
and
then
disconnect
the
XSCF
BB
control
cable.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
126
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...