Table
3-20
Problems
resolved
in
XCP
2050
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
130319-003
x
x
x
If
the
shutdown
-i5
command
and
power-off
command
compete
for
power-off
of
the
PPAR
when
the
former
is
executed
in
the
control
domain
or
the
latter
is
executed
from
the
ok
prompt
while
power-off
of
the
physical
partition
(PPAR)
is
performed
with
the
poweroff
(8)
command,
"SCF:PPAR
issued
power-off
request
(PPARID
X)"
may
be
registered
many
times.
Ignore
the
registered
event
log,
because
the
PPAR
has
been
normally
powered
off.
RTIF2-
130329-004
x
In
a
system
with
building
block
configuration,
if
the
following
operations
are
performed
during
power-on
of
the
physical
partition
(PPAR),
connection
to
the
control
domain
console
may
not
be
possible.
1.
XSCF
for
any
of
the
SPARC
M10-4S
units
constituting
PPAR
is
reset.
2.
Switching
of
the
master
XSCF
and
standby
XSCF
occurs.
3.
XSCF
of
the
SPARC
M10-4S
that
was
reset
in
1.
is
reset
again.
There
is
no
effective
workaround.
Reset
the
master
XSCF
using
the
switchscf(8)
command.
RTIF2-
130329-006
x
If
XSCF
of
SPARC
M10-4S
belonging
to
the
physical
partition
(PPAR)
in
operation
is
reset
due
to
a
panic
or
watchdog
timeout
while
the
master
XSCF
and
the
standby
XSCF
are
restarting
simultaneously,
connection
to
the
control
domain
console
may
not
be
possible.
There
is
no
effective
workaround.
Power
off
the
PPAR
by
using
the
poweroff
-f
command,
and
then
power
it
on
again.
RTIF2-
130516-003
x
x
x
If
the
XSCF
load
is
high,
the
following
warning
message
may
be
output,
indicating
the
power
supply
unit
(PSU)
as
a
suspected
location.
Insufficient
FAN
rotation
speed
PSU
voltage
out
of
range
error
PSU
output
current
too
high
PSU
over
temperature
warning
There
is
no
workaround.
This
is
a
warning
message,
so
you
can
operate
it
as
it
is.
Ignore
the
message.
Chapter
3
Information
on
Software
141
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...