Table
3-6
Problems
resolved
in
XCP
2240
(continued)
SPARC
M10-
RTINo.
1
4
4S
Description
Workaround
RTIF2-
140715-001
x
In
SPARC
M10-1,
if
the
power
supply
unit
(PSU)
has
a
redundant
configuration
and
the
power
cable
connected
to
one
of
the
power
supply
units
is
pulled
out,
a
PSU
error
may
be
erroneously
detected,
and
the
SPARC
M10-1
chassis
Check
LED
(amber)
may
go
on.
At
this
time,
executing
the
showlogs
error
command
outputs
the
"Msg:
PSU
failed"
log.
There
is
no
effective
workaround.
[How
to
restore]
Use
either
of
the
following
procedures.
-
How
to
restore
1
Turn
off
the
power
to
the
SPARC
M10
chassis
connected
to
the
PCI
expansion
unit.
Then
disconnect
both
PCI
expansion
unit
power
cables
(AC
OFF).
Then,
wait
for
30
seconds
to
reconnect
the
cables
(AC
ON).
-
How
to
restore
2
Perform
pseudo
active
replacement
of
the
PSU
in
which
the
error
has
been
detected
(temporarily
remove
the
PSU
and
then
reinstall
it).
When
performing
pseudo
replacement
of
the
PSU,
use
the
replacefru(8)
command.
Note
that
the
fieldeng
privilege
is
required
to
execute
the
replacefru(8)
command.
RTIF2-
141016-001
x
x
x
AC
input
power
may
be
incorrectly
determined
to
have
a
mix
of
100
V
and
200
V
if
any
of
the
power
supply
units
(PSU)
in
redundant
configuration
triggers
an
AC
input
error,
and
then
power
loss/recovery
repeats
in
a
short
time.
Consequently,
though
system
operation
may
continue
when
power
is
recovered,
two
PSUs
are
degraded
with
the
"PSU
shortage
(power
off
started)"
message
displayed
and
the
system
stops.
There
is
no
effective
workaround.
Replace
the
faulty
PSU.
Chapter
3
Information
on
Software
87
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...