Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
130305-022
x
The
poweron(8)
command
may
fail
with
the
output
of
the
following
message
if
an
error
log
showing
that
"XSCF
hang-up
is
detected"
was
detected
and
an
"unknown"
system
board
(PSB)
was
found
by
the
showboards(8)
command.
The
same
can
be
said
for
the
instruction
of
power-on
using
the
XSCF
Web,
APCS,
or
the
power
supply
interlocking.
Not
powering
on
:
An
internal
error
has
occurred.
Please
contact
your
system
administrator.
There
is
no
effective
workaround.
Use
the
showboards(8)
command
to
replace
the
XSCF
of
the
PSB,
which
is
shown
as
"unknown".
RTIF2-
130305-023
x
If
an
error
occurs
in
the
DC-DC
converter
of
a
crossbar
unit,
"XB-XB
interface
link-up
error."
is
erroneously
registered
instead
of
the
correct
error
log
of
"LSI
detected
errors
with
power
subsystem
failure."
There
is
no
effective
workaround.
Check
for
power
errors
if
the
error
log
of
"XB-XB
interface
link-up
error"
was
registered.
Ignore
the
error
log
for
"XB-XB
interface
link-up
error"
if
a
power
error
has
occurred.
RTIF2-
130305-025
x
If
the
poweroff(8)
command
is
executed
in
the
system
that
has
more
than
one
physical
partition
(PPAR),
it
takes
time
for
the
processing
because
the
power
of
the
PPARs
is
disconnected
one
by
one.
Depending
on
the
system
configuration,
it
may
take
about
one
hour.
There
is
no
effective
workaround.
RTIF2-
130329-005
x
When
you
turn
on
the
input
power
supply
in
SPARC
M10-1,
READY
LED
of
XSCF
remains
blinking
and
the
system
may
not
start.
There
is
no
effective
workaround.
Power
off
the
input
power
supply
and
then
power
it
on
again.
RTIF2-
130410-001
x
The
diagnosis
of
the
system
board
may
fail
during
the
power-off
of
the
system
board
(PSB)
by
executing
the
diagxbu(8)
or
testsb(8)
command,
displaying
the
following
message.
[Warning:010]
An
internal
error
has
occurred.
There
is
no
effective
workaround.
Execute
the
showboards(8)
command
to
check
that
the
[Pwr]
field
of
the
relevant
PSB
is
set
to
"n".
If
the
field
is
set
to
"y",
execute
the
showboards(8)
command
every
few
minutes
to
check
that
the
field
changes
to
"n".
RTIF2-
130410-002
x
The
switching
of
an
XSCF
may
fail
if
the
XSCF
is
switched
by
executing
the
switchscf(8)
command
while
a
physical
partition
(PPAR)
is
being
powered
on.
Do
not
switch
an
XSCF
by
using
the
switchscf(8)
command
while
a
PPAR
is
being
powered
on.
Chapter
3
Information
on
Software
43
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...