Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
failures
may
not
be
detected,
and
the
physical
partition
(PPAR)
may
hang
up.
For
a
DDC
failure,
confirm
whether
any
of
the
following
error
logs
is
registered.
Msg:
Critical
low
voltage
error
Or
Msg:
Critical
high
voltage
error
Or
Msg:
Power
subsystem
failure
RTIF2-
140407-006
x
For
a
SPARC
M10-4S
chassis
with
the
XSCF
stopped,
or
with
the
input
power
off
(AC
OFF),
even
if
you
execute
the
initbb
-f
command
to
forcibly
disconnect
the
chassis
from
the
system,
the
chassis
remains
assigned
to
the
physical
partition
(PPAR).
To
check
this
phenomenon,
execute
the
showboards(8)
command
to
confirm
whether
Assignment
of
the
target
SPARC
M10-4S
chassis
(PSB)
remains
"Assigned".
XSCF>
showboards
-av
PSB
R
PPAR-ID(LSB)
Assignment
Pwr
Conn
Conf
Test
Fault
----
-
------------
-----------
----
----
----
-------
--------
00-0
00(00)
Assigned
y
y
y
Passed
Normal
01-0
*
00(01)
Assigned
n
n
n
Unmount
Normal
There
is
no
effective
workaround.
[How
to
restore]
Perform
the
following
on
the
disconnected
SPARC
M10-4S
chassis.
1.
Execute
the
replacefru(8)
command
to
replace
the
chassis.
2.
Power
on
(AC
ON)
the
replacement
chassis.
-
If
the
READY
LED
of
the
XSCF
or
XSCF
unit
is
lit
a.
Complete
replacefru(8)
command
execution
by
following
the
maintenance
menu.
b.
Execute
the
initbb(8)
command
to
disconnect
the
chassis
from
the
system.
-
If
the
READY
LED
of
the
XSCF
or
XSCF
unit
is
not
lit
Remove
the
chassis
and
replace
the
XSCF
unit
or
CPU
memory
unit
lower
(CMUL)
where
a
failure
is
suspected.
RTIF2-
140407-008
x
If
the
poweroff(8)
command
is
executed
and
the
master
chassis
XSCF
is
reset
during
the
time
that
it
takes
for
a
prompt
to
be
returned,
the
following
power
on/power
off
operation
cannot
be
executed.
There
is
no
effective
workaround.
If
this
phenomenon
occurs,
turn
off
the
input
power
to
all
chassis
and
then
turn
it
on
again.
RTIF2-
140409-001
x
x
x
An
error
may
be
detected
in
the
Realtime
Clock
(RTC)
built
into
the
SPARC
M10
system
and
XSCF
may
not
start.
There
is
no
effective
workaround.
[How
to
restore]
Turn
off
the
input
power
to
the
system
and
then
turn
it
on
again
(AC
OFF/ON).
RTIF2-
140409-002
x
x
x
If
you
disconnect
and
then
connect
the
USB
memory
while
the
executed
snapshot(8)
command
is
collecting
information
into
the
memory,
the
hardware
error
below
may
be
detected.
Do
not
connect
and
then
disconnect
the
USB
memory
while
information
is
being
collected
into
the
memory
by
the
snapshot(8)
command.
[How
to
restore]
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
64
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...