Table
3-5
Problems
that
might
occur
with
XCP
2240
and
workarounds
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
130410-003
x
If
a
physical
partition
(PPAR)
is
powered
on
in
the
system
that
satisfies
all
the
following
conditions,
other
PPAR
may
also
be
powered
on.
-
The
power
supply
interlocking
is
enabled
with
the
setremotepwrmgmt
(8)
command.
-
A
node
is
created
whose
SubNodeID
is
not
set
in
a
power
supply
interlocking
management
item.
-
Multiple
PPARs
are
configured.
-
When
power
supply
interlocking
is
not
necessary
Disable
power
supply
interlocking
with
setremotepwrmgmt
-c
disable
and
then
delete
the
power
supply
interlocking
setting
with
the
clearremotepwrmgmt
(8)
command.
-
When
power
supply
interlocking
is
necessary
If
the
system
has
multiple
PPARs,
create
a
management
file
for
power
supply
interlocking
by
specifying
a
PPAR-ID
as
a
SubNodeID,
and
then
register
the
power
supply
interlocking
setting
with
setremotepwrmgmt
-c
config.
RTIF2-
130516-002
x
If
XSCF
switching
or
an
XSCF
reset
occurs
while
the
physical
partition
(PPAR)
is
being
powered
off,
it
may
be
impossible
to
turn
off
the
power.
There
is
no
effective
workaround.
While
powering
off
PPAR,
do
not
use
the
switchscf(8)
command
to
perform
XSCF
switching
or
the
rebootxscf(8)
command
to
perform
an
XSCF
reset.
RTIF2-
130516-004
x
If
a
hardware
failure
occurs
in
a
4BB
or
greater
configuration,
automatic
cluster
switching
may
fail.
If
16
or
more
guest
nodes
are
incorporated
into
a
single
cluster,
the
following
warning
message
may
be
output
to
the
console
of
the
control
domain.
SA
SA_xscf????.so
to
test
host
???
failed
If
automatic
cluster
switching
fails,
follow
the
procedure
in
the
manual
of
the
cluster
software
to
perform
switching
manually.
RTIF2-
130516-006
x
If
XSCF
switching
occurs
while
multiple
physical
partitions
(PPARs)
are
being
powered
on
at
the
same
time,
it
may
take
more
than
usual
to
power
them
on.
There
is
no
effective
workaround.
Do
not
switch
an
XSCF
by
using
the
switchscf(8)
command
while
PPARs
are
being
powered
on.
Fujitsu
M10/SPARC
M10
Systems
Product
Notes
for
XCP
Version
2240
・
March
2015
44
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...