Table
3-20
Problems
resolved
in
XCP
2050
(continued)
SPARC
M10-
RTI
No.
1
4
4S
Description
Workaround
RTIF2-
131107-002
x
x
x
If
the
input
power
to
the
system
is
turned
on,
the
XSCF
is
reset,
or
the
XCP
firmware
is
updated,
the
"SCF
Diagnosis
initialize
RTC"
error
is
erroneously
detected,
causing
the
following
phenomena
to
occur.
[Phenomenon
1]
The
XSCF
time
may
return
to
January
1,
1970.
[Phenomenon
2]
The
time
difference
between
the
XSCF
and
all
physical
partitions
(PPARs)
may
become
a
value
of
1.3
billion
seconds
or
more.
You
can
check
this
phenomenon
by
executing
the
showdateoffset(8)
command,
since
the
time
difference
between
the
XSCF
and
all
the
PPARs
is
displayed
as
a
value
of
"1300000000
sec"
or
more.
XSCF>
showdateoffset
-a
PPAR-ID
Domain
Date
Offset
00
1300000100
sec
01
1300000100
sec
:
:
15
1300000100
sec
[Phenomenon
3]
If
you
reset
the
PPAR
or
power
off
and
on
the
PPAR,
the
Oracle
Solaris
time
may
return
to
January
1,
1970.
There
is
no
effective
workaround.
Update
to
firmware
version
XCP
2050
or
later.
[How
to
restore]
For
details,
see
XSCF>
showdomainconfig
-p
0
20xx-yy-zz
hh:mm:ss
PPAR-ID
:0
Booting
config
Reconstructing
the
logical
domain
(RTIF2-130528-001)
To
resolve
this
problem
when
you
have
saved
the
configuration
information
of
the
logical
domain
and
are
operating
the
system
with
a
configuration
other
than
factory-default,
you
must
reconstruct
the
logical
domain
configuration
after
update
of
the
XCP
firmware
through
the
following
procedure:
1.
Check
the
current
configuration
information
of
the
logical
domain
stored
in
XSCF.
This
example
assumes
that
the
name
of
the
saved
logical
domain
configuration
information
is
config1.
Chapter
3
Information
on
Software
143
Summary of Contents for M10 Series
Page 8: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 viii ...
Page 14: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 xiv ...
Page 24: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 10 ...
Page 192: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 178 ...
Page 200: ...Fujitsu M10 SPARC M10 Systems Product Notes for XCP Version 2240 March 2015 186 ...