Warning and Caution
WARNINGS
Do not touch the electrodes when the splicer is on and power is supplied to the
unit. The electrodes generate high voltage and high temperatures that may cause
a severe shock or burn.
Note Arc discharge stops when wind protector is opened.
Turn the splicer off and
disconnect the AC power cord before replacing electrodes.
Safety glasses should always be worn during fiber preparation and splicing
operation. Fiber fragments can be extremely dangerous if it comes into contact
with the eye, skin, or is ingested.
Use only proper power source.
•
Proper AC power source is AC100-240V, 50-60Hz. Check the AC power
source before use. Proper DC power source is DC10-12V. Improper AC or
DC power source may cause fuming, electric shock or equipment damage and
may result in personal injury, death or fire.
•
AC generators commonly produce abnormally high AC output voltage or
irregular frequencies. Measure the output AC voltage with a circuit tester
before connecting the AC power cord. Such abnormally high voltage or
frequency from a generator may cause fuming, electric shock or equipment
damage and may result in personal injury, death or fire. Make sure the
generator is regularly checked and serviced.
•
When an AC generator that AC voltage is 220-240V turns on the “HIGH AC
INPUT” lamp of the AC adapter, or when it breaks the AC adapter several
times, it outputs dangerous high voltage. Fujikura Ltd. recommends following
measures.
(1) Connect a step down transformer between the generator and the AC
adapter in order to lower the AC voltage from AC220-240V to
AC100-120V.
(2) Or, use an AC generator that AC voltage is AC100V.
(3) Or, use an AC generator that has an inverter circuit to stabilize the output.
Do not modify, abuse, heat or excessively pull on the supplied AC cord. The use
of a damaged cord may cause fuming, electric shock or equipment damage and
may result in personal injury, death or fire.
The FSM-50S uses a three-prong (core) AC cord that contains an earthed ground
safety mechanism. The splicer MUST be Grounded. Use only the supplied
three-prong (core) AC power cord. NEVER use a two-prong (core) power cord,
extension cable or plug.
!