78
Error Message List
Error
Code
Error
Message
Reason Solution
Dust or dirt is on the
fiber surface.
Completely prepare the fiber again
(strip, clean and cleave).
The left and right fiber
types are different.
Select the suitable splice mode.
Pressing the
SET
key cancels the
error and continues the splice
operation.
08
Cannot detect
fiber in
AUTO mode
Splicing non-standard
fibers.
The AUTO mode can identify
standard SM, DS, MM and NZDS
fiber only.
01
Strong
Arc Power
Unable to calibrate due
to strong arc.
02
Weak
Arc Power
Unable to calibrate due
to weak arc.
03
Too Left
Arc
Unable to calibrate due
to poor arc field position
(too far left).
09
04
Too Right
Arc
Unable to calibrate due
to poor arc field position
(too far right).
Replace the electrodes by using the
[Electrode Replace] function. If this
does not eliminate the problem,
consult your nearest sales agency.
The fiber stuff amount is
insufficient.
Execute the [Motor Calibration]
function. If using other splice
modes, check the [Overlap] setting
in the splice mode.
10
Fiber
Separation
The pre-fuse power or
pre-fuse time is set too
high.
Check the [Prefuse Power] and
[Prefuse Time] settings in the splice
mode.
01
L-Bad Fiber
Position
11
02
R-Bad Fiber
Position
The fiber is not set
correctly at the bottom
of the V-groove.
Press
RESET
, and re-position the
fiber again to seat it correctly at the
bottom of the V-groove.
12
No Arc
Discharge
Arc Discharge did not
occur.
• Assure the electrodes are in proper
position.
• Replace the electrodes.
• Consult your nearest sales agency.