48
Splice Menu
2.
Heater Mode
There are 10 user-programmable heating modes. Select one best suitable for the
protection sleeve used.
Each tube-heating mode is optimized for a type of Fujikura protection sleeve. These
modes can be found in database area for reference. Copy the appropriate one and paste it
to the user-programmable area. The operator can edit the user-programmable modes.
Data Base
Parameter Description
60mm
For standard 60mm protection sleeve,
such as Fujikura FP-03 or FP-03M protection sleeves.
40mm
For standard 40mm protection sleeves,
such as Fujikura FP-03 (L=40).
34mmA
For 34mm micro sleeves, such as Fujikura FPS01-250-34.
25mmA
For 25mm micro sleeves, such as Fujikura FPS01-250-25.
20mmA
For 20mm micro sleeves, such as Fujikura FPS01-250-20.
40mmB
For 40mm micro sleeves, such as Fujikura FPS01-400-40.
34mmB
For 34mm micro sleeves, such as Fujikura FPS01-400-34.
25mmB
For 25mm micro sleeves, such as Fujikura FPS01-400-25.
20mmB
For 20mm micro sleeves, such as Fujikura FPS01-400-20.
45mmC
For 45mm micro sleeves, such as Fujikura FPS01-900-45.
34mmC
For 34mm micro sleeves, such as Fujikura FPS01-900-34.
25mmC
For 25mm micro sleeves, such as Fujikura FPS01-900-25.
Summary of Contents for FSM-50S
Page 2: ......