54
Splice Menu
4.
Splice Option
Common parameters for all the modes for splicing and tube heating can be set.
(1) Select [Splice Option] in [Splice
Menu] to display [Splice Option]
menu.
(2) Select a parameter to be changed.
(3) Press
to change values, and press
to enter.
Setting parameters
Parameter Description
Auto Start
If “Auto Start” is set to "ON", splicing starts automatically as
soon as the wind protector is closed. Fibers should be prepared
and placed into the splicer in advance.
Pause1
If "Pause1” is set to “ON”, splicing operation pauses when fibers
are forwarded to gap-set position. Cleave angles are displayed
during the pause.
Pause2
If “Pause 2” is set to "ON", splicing operation pauses after fiber
alignment is completed. With ECF “ON”, core-to-core
alignment is made after this pause.
Data Display
Cleave Angle
“ON” displays the results of cleave angle measurement of the
left and right fibers. In other splice modes, the results of core
angle measurement are also displayed.
Axis Offset
“ON” displays the amount of core axial offset and the amount of
cladding axial offset on the screen.
Splice Setting
Select the [Splice Option]
in the [Splice Menu]
Summary of Contents for FSM-50S