17
Basic Operation
3.
Setting sleeve centering device
Open tube heater lid, and slide gauge
indicator to match the length of
protection sleeve used.
4.
Cleaning optical fiber
Clean optical fiber with alcohol-impregnated gauze or lint-free tissue approximately
100mm from the tip. Dust particulates from the fiber coating surface can enter inside the
protection sleeve and might result in a future fiber break or attenuation increase.
5.
Placing protection sleeve over fiber
Place the protection sleeve over
the fiber.
6.
Stripping and cleaning fiber
Strip outer coating 30 to 40 mm from its tip with a stripping tool. Clean the fiber with
alcohol impregnated gauze or lint-free tissue thoroughly. Use fresh gauze or wipe only.
Do not use gauze or wipe twice.
• Use a high quality alcohol, greater than 99% pure.
Stripping
Cleaning
Move by finger
Sleeve length
Fiber protection sleeve
Pass fiber
Fiber