12
Basic Operation
1.
Inserting Power Supply into Splicer
For AC operation or DC operation with external battery, use AC adapter (ADC-11). For
battery operation, use detachable battery (BTR-06S/L). The Power Unit Dock, located on
the splicer body, can accommodate both power supplies (ADC-11 and BTR-06S/L).
1-1.
Inserting or detaching power unit
Inserting power supply unit
Insert power unit into Power unit dock until
it clicks into place.
Detaching power supply unit.
Turn off the splicer. Push the release button,
located on the side of the splicer body, and
remove the power supply out of the splice
body.
1-2.
AC Operation
Plug the supplied AC cord into the AC inlet
of the AC adapter. The power ON LED in
the AC adapter turns on (green color) when
suitable AC voltage is supplied. In case of
AC350V
(
Peak Voltage: 490V
)
or greater is
supplied, the AC adapter protection circuit
shuts down the AC output and the AC
Warning LED [HIGH ~ INPUT] turns on
(red color). And, in case of AC400V (Peak
Voltage: 560V) or greater is supplied, the
AC adapter will be immediately broken.
Release button
Pull the power unit
• Do not cover any of the AC adapter vents. Allow at least one-inch air gap
between wall and splicer in order to circulate fresh air.
Insert
Power ON LED
(GREEN)
AC warning
LED (RED)