90
Splice Mode
Parameter
Description
XY Alignment
Alignment
Method
Selects XY Alignment [OFF], [PAS], [EV] or [P-Meter]
Note : [EV] is able to be only FSM-100M+/P+
Alignment
Mode
Alignment Method: [PAS]
Alignment Modes [Core] [Clad] [Manual]
Alignment Method: [EV]
Note : FSM-100M+/P+ Only
Alignment Modes [Core]
Alignment Method: [P-Meter]
Alignment Modes: [Max(P-Meter)], [Min(P-Meter)], [Manual]
ECF
Only for Alignment Mode: [Core]
Set the ECF ON or OFF.
Set the axial offset ratio for ECF.
Attenuation
Set the Attenuation ON or OFF.
If Attenuation is ON, the following setting is ready to edit.
Unit Of Align
Target
Sets the units for align target for attenuation splice.
XY
Individually
Set the XY Individually ON or OFF.
*Only if the [μm] is selected, the setting of XY Individually is available.
Align Target
Align Target units [μm], [dB], and [dBm].
*The setting of XY Individually is available in the following conditions
Unit Of Align Target:[dB] [dBm] [μm]
XY Individually: [OFF]
XY Alignment: [PAS]
Selects Alignment Mode
[Core], [Clad] or [Manual]
Alignment Method:
[P-Meter]
Selects Alignment Mode
[Max], [Min] or [Manual]