Splice Mode
6-3.
Splicing Using Manual X/Y Alignment
This method is to manually align and splice fibers. The following procedure uses
automatic gap set of the fibers, as in the case of fully automatic splicing. However,
X/Y alignment is performed manually. For this method, the Gap Set parameter is set
to [Splicing], and other parameters of automatic gap set are utilized. The X/Y
Alignment Method is set to [PAS] and the Alignment Mode is set to [Manual], as
shown in the screen images below.
Operation proceeds as follows:
(1)
Press the SET key to drive the fibers forward automatically. The fibers stop
moving forward at the programmed gapset position. The screen images
below will appear.
Main Monitor
Sub Monitor