129
Heater Mode
2.
Heater Menu (Sleeve Heater)
There are 30 user-programmable heating modes. Select the most suitable mode for
the protection sleeve used.
Each tube-heating mode is optimized for a type of Fujikura protection sleeve. These
modes can be found in the database area for reference. Select the most appropriate
database mode for the Sleeve Type in the Edit Heater Mode menu in order to paste it
to the user-programmable area. The operator can edit the user-programmable modes
as required (for example, to optimize for non-Fujikura sleeves, or a special length or
type of sleeve).
Parameter
Description
60mm
For standard 60mm protection sleeves, such as the Fujikura FP-03
or FP-03M protection sleeve.
60Ny8
For standard 60mm protection sleeves, such as the Fujikura FP-03
or FP-03M protection sleeve.
Note: This mode is optimized for fibers with a 900um jacket such
as Nylon or Hytrel. It is also optimized for an 8mm cleave length.
40mm
For standard 40mm protection sleeves, such as the Fujikura FP-03
(L=40).
45mmC
For 45mm micro sleeves, such as the Fujikura FPS01-900-45.
34mmC
For 34mm micro sleeves, such as the Fujikura FPS01-900-34.
25mmC
For 25mm micro sleeves, such as the Fujikura FPS01-900-25.
40mmB
For 40mm micro sleeves, such as the Fujikura FPS01-400-40.
34mmB
For 34mm micro sleeves, such as the Fujikura FPS01-400-34.
25mmB
For 25mm micro sleeves, such as the Fujikura FPS01-400-25.
20mmB
For 20mm micro sleeves, such as the Fujikura FPS01-400-20.
Dimensions of the protection sleeve after shrinking:
Example of FP-03 (60)
Length
:
60~62mm
Diameter
:
3.3~3.7mm
The dimensions of the splice protection sleeve after the heat shrink operation
will vary depending on the diameter of the fiber and fiber coating.
Length
Diameter