113
Splice Mode
(2)
By pressing the HELP key, the following display appears to guide manual
alignment operation.
(3)
Select a motor to be manually moved by pressing the Right/Left key. The
selected motor is displayed in the monitor. Motor speed can be set to “Fast”
or “Slow” by pressing the ENT key.
Press the Up/Down key to move the
selected motor to drive the fibers forward or backward.
(4)
During manual alignment, the vertical and horizontal grid lines on the X/Y
fiber image display are present to help guide alignment. The horizontal grid
line helps guide lateral alignment of the fibers using the X and Y motors.
The two vertical grid lines show the proper gap set positions for the left and
right fiber cleaved ends. When automatic gap set is initially performed, the
fiber ends will be aligned with the vertical grid lines. If the fiber end
positions move slightly during X and Y motor movement as the fibers are
manually aligned, by switching to the ZL motor the left fiber can be
realigned to the left vertical grid line and the ZR motor can be used to
realign the right fiber to the right vertical grid line. The grid lines can be
toggled ON and OFF by using the ESC key.
(5)
After manual alignment is completed, press the SET key to perform the
fusion arc and splice the fibers. The splicing process will then proceed
according to the splice mode parameters that have been programmed for
[Prefuse], [Overlap] and [Main Arc]. Loss estimation will not be performed.
Main Monitor