115
Splice Mode
8.
Power Meter Feedback Alignment
The FSM-100 series can be connected to a power meter via GP-IB port and USB port.
Therefore, the RIDS alignment method can be used with power meter and
polarizer/depolarizer.
Power Meter Alignment by the GP-IB Port
Set the GP-IB address and type of the optical power meter at the [Machine Settings].
See Section [
] → [Power Meter Alignment]
XY Align with Power Meter Feedback
Connect the splicer, light source, and power meter as shown.
The splicer aligns X- and Y-axis to make the power meter value as strong (weak) as
possible MAX (MIN).
θ Align with Power Meter Feedback
Connect the splicer, light source, power meter, polarizer, and depolarizer as shown.
Set [θ Align] to [P Max] or [P Min]. See [Checking or Editing Splice Mode]. In case
of [P Max], the splicer aligns θ-axis to make the power meter value as high as
possible, MAX. On the other hand, in case of [P Min], the splicer aligns θ-axis to
make the power meter value as low as possible, MIN.
Light Source
Power Meter
Fiber
Fiber
GP-IB Cable
FSM-100M/M+/P/P+
FSM-100P/P+
Light Source
Power Meter
Fiber
Fiber
Polarizer
Depolarizer
GP-IB Cable