96
Splice Mode
[Special Function]
Parameter
Description
ARC
Arc Power
Set the Arc Power.
Depending on the selected Arc Calibration Method, [STD], [SP],
[NC], the Arc Power may be set automatically.
Start Time
Set the starting time of the arc discharge.
Finish Time
Set the ending time of the arc discharge.
On-Time
Set the On-Time of the arc discharge (for pulsed arcing).
Off-Time
Set the Off-Time of the arc discharge (for pulsed arcing).
Electrode
swing
Note:1
Set “ON” or “OFF”. When “ON” is selected it is necessary to set the
following 2 [Electrode Swing] parameters.
While [Measurement Method] is set to "P-Meter", the electrode swing
function is inactive.
Swing home
position
Note:1
This is to set the electrode swing home position.
Swing stroke
Note:1
This is to set the electrode swing up/down stroke distance
Motor [1
・
2
・
3
・
4]
Motor
Select the Sweep, ZL, ZR, X, Y, θL, or θR motor.
Up to 4 motors may be selected and controlled for each Special Function
step.
Motor settings for all 4 motors may be controlled independently using
the parameters below.
Direction
[Direction] Set the direction of motor motion.
Start Time
[Start Time] Set the motor motion start time.
Finish Time
[Finish Time] Set the motor motion ending time.
Initial Speed [Initial Speed] Set the initial motor speed.
Acceleration [Acceleration] Set motor speed acceleration.
Acceleration
Type
Select the types of acceleration, [Type 1], [Type 2+], [Type 2-], [Type
3+] or [Type 3-].
[Type 1]: Constant acceleration
[Type 2+], [Type 2-], [Type 3+], [Type 3-]: These are special types of
acceleration used for tapering.
* For details, see section [Splice Mode] [Special Function settings for
tapering].
Note1: FSM-100M+/P+ only