84
Splice Mode
Parameter
Description
Stage Positions at Start
Sweep
Initial
Position
When the splicer resets or an operator changes the splice mode, the
sweep motor moves to the indicated position.
Except Z Stages
These parameters determine what action is taken by Z Stage motors
and all other motors (with the exception of End-View mirror motor, Va
and clamp motors) during [Reset] or when the splice mode setting is
changed.
[Predefined]: Motors move back to predefined “home” positions
automatically
NOTE:
[Predefined] is the default condition
[Keep]: Motors remain stationary at their present positions even if set
to that position manually or by other operations such as automatic
alignment. The present motor position will be maintained if [Reset] is
performed or if the wind protector is opened.
When the operator sets a value except [Center] to [Sweep Initial
Position], the splicer doesn’t display [Z stages] and executes as
[Predefined].
Z Stages