12
091-430
[Cause]
The drum cartridge life is over.
[Remedy] Switch off the machine power, make sure that the display is blank,
and then switch on the machine power. If the same message is
displayed again, contact our Customer Support Center.
Refer to "Replacing the Drum Cartridge" (P.182).
091-440
[Cause]
The drum cartridge need to be replaced soon.
[Remedy] Prepare a new drum cartridge.
Refer to "Replacing the Drum Cartridge" (P.182).
091-441
[Cause]
The drum cartridge need to be replaced soon.
[Remedy] Replace the drum cartridge. Contact your local Fuji Xerox
representative or sales representative.
091-914
091-915
091-916
[Cause]
An error occurred with the drum cartridge.
[Remedy] Switch off the machine power, make sure that the display is blank,
and then switch on the machine power. If the same message is
displayed again, contact our Customer Support Center.
091-921
[Cause]
An error occurred with the drum cartridge.
[Remedy] Replace the drum cartridge. Contact your local Fuji Xerox
representative or sales representative.
092-660
[Cause]
A drum cartridge error occurred.
[Remedy] Switch off the machine power, make sure that the display is blank,
and then switch on the machine power.
092-661
[Cause]
Temperature SNR (in CRU) value is out of range.
[Remedy] Exchange the Sensor unit, and switch off the machine power, make
sure that the display is blank, and then switch on the machine
power.
092-668
[Cause]
ATC SNR (in drum cartridge) value is out of range.
[Remedy] Switch off the machine power, make sure that the display is blank,
and then switch on the machine power.
092-910
[Cause]
An error occurred.
[Remedy] Switch off the machine power, make sure that the display is blank,
and then switch on the machine power.
093-312
[Cause]
An error occurred with the toner cartridge.
[Remedy] Switch off the machine power, make sure that the display is blank,
and then switch on the machine power. If the same message is
displayed again, contact our Customer Support Center.
093-400
[Cause]
There is no more toner in the toner cartridge.
[Remedy] Replace the toner cartridge.
093-406
[Cause]
The toner cartridge needs to be replaced soon.
[Remedy] Prepare a new toner cartridge.
093-912
[Cause]
There is no more toner in the toner cartridge.
[Remedy] Replace the toner cartridge.
093-956
[Cause]
There is no more toner in the toner cartridge.
[Remedy] Remove the seal on the drum cartridge.
Error Code
Cause and Remedy
Summary of Contents for DocuCentreS2320
Page 1: ...1 DocuCentre S2320 User Guide DocuCentre S2520 ...
Page 26: ...1 Before Using the Machine 26 Before Using the Machine 1 ...
Page 58: ...2 Environment Settings 58 Environment Settings 2 ...
Page 80: ...3 Product Overview 80 Product Overview 3 ...
Page 94: ...4 Loading Paper 94 Loading Paper 4 ...
Page 160: ...8 Tools 160 Tools 8 ...
Page 176: ...10 Job Status 176 Job Status 10 ...
Page 190: ...11 Maintenance 190 Maintenance 11 ...
Page 252: ...13 Appendix 252 Appendix 13 ...