3.2 Running Mode
3-5
Chap. 3
OP
ERA
T
ION US
ING
THE
K
EYP
AD
Setting up the set frequency with the and keys under the PID control
To set the set frequency with the and keys under the PID control, you need to specify the
following conditions:
- Set function code F01 to "0: Keypad operation."
- Select frequency setting-1 (Frequency settings from communications link: Disabled, and Multistep
frequency settings: Disabled) as manual speed command.
- Set the LED monitor to the speed monitor in Running mode.
The above setting is impossible in any operation mode except Running mode.
The setting procedure is the same as that for usual frequency setting.
If you press the or key in any conditions other than those described above, the following will
appear:
Frequency
setting 1 (F01)
Frequency
setting from
communications
link
Multistep
frequency
setting
PID control
cancelled
Displayed using
or
key
PID enabled
0
Disabled
Disabled
Cancelled
Frequency setting by keypad
PID enabled
PID output (as final frequency
command)
Other than the above
Cancelled
Manual speed command
currently selected (frequency
setting)
• When setting the frequency and others with the / keys, the lowest digit on the
display will blink. Change the setting, starting from the lowest digit and the cursor will
move gradually to the next digit to be changed.
• When the data is to be changed rapidly, hold down the
key for 1 second or longer,
and the blinking cursor will move to the next digit where the data can be changed
(cursor movement)
3.2.3 Monitor the Running Status
In Running mode, the seven items listed below can be monitored. Immediately after the inverter is
turned on, the monitor item specified by function code E43 is displayed. Press the
key to switch
between monitor items.
Table 3.1 Monitor Items
Monitor Items
Display Sample on
the LED monitor
Meaning of Displayed Value
Speed monitor
(Hz, rpm, m/min, min)
50.00
Refer to Table 3.2.
Output current (A)
1.90A
Detected value
Input power (kW)
0.40P
P
: An alternative expression for kW
Output voltage (V)
200U
Commanded value
PID process command
(Note)
10.00
PID feedback amount
(Note)
9.00
(PID process command or PID feedback amount)
×
(PID display coefficient A – B) + B
PID display coefficient A and B: Refer to function
codes E40 and E41
Timer (sec)
(Note)
6
Remaining effective timer count
Note: The PID process command and PID feedback amount are displayed only under the PID control using a process
command (J01 = 1 or 2). Further, the timer (for timer operation) is only displayed when timer is enabled (C21 = 1).
Summary of Contents for frenic mini series
Page 1: ...USER S MANUAL Fuji Electric Co Ltd MEH446...
Page 2: ...Compact Inverter User s Manual...
Page 62: ...4 4 4 3 Drive Command Generator Figure 4 2 Drive Command Generator...
Page 66: ...4 8 Figure 4 3 d Terminal Command Decoder ORing with Link Commands Ignoring Link Commands...
Page 68: ...4 10 4 5 Digital Output Selector Figure 4 4 Digital Output Signal Selector...
Page 70: ...4 12 4 6 Analog Output FMA Selector Figure 4 5 Analog Output FMA Selector...
Page 74: ...4 16 4 8 PID Frequency Command Generator Figure 4 7 PID Frequency Command Generator...
Page 81: ...Part 3 Peripheral Equipment and Options Chapter 6 SELECTING PERIPHERAL EQUIPMENT...
Page 124: ...Part 5 Specifications Chapter 8 SPECIFICATIONS Chapter 9 FUNCTION CODES...
Page 134: ...8 3 Common Specifications 8 9 Chap 8 SPECIFICATIONS 8 3 Common Specifications...
Page 135: ...8 10...
Page 257: ...App H Replacement Information A 33 App FVR C11S vs FRENIC Mini...
Page 261: ...Glossary This glossary explains the technical terms that are frequently used in this manual...