9.2 Details of Function Codes
9-33
Chap. 9
FUNCTI
ON C
O
DE
S
For ordinary set frequency (J01 = 0)
For PID control (J01 = 1 or 2)
If (IVS) is:
Set frequency
If (IVS) is:
Selected PID control
(J01)
PID operation
OFF
Normal
operation
OFF
1: Normal operation
Normal
ON
Inverse
operation
ON
1: Normal operation
Inverse
OFF
2: Inverse operation
Inverse
ON
2: Inverse operation
Normal
Select link operation--(LE)
(Function code data = 24)
Turning ON the (LE) command selects link operation. The inverter will run the motor with
the frequency command or drive command given via the RS485 communications facility
defined by function code H30.
If the (LE) command is not assigned to any terminal, the inverter will interpret (LE) as
being always ON.
Refer to Chapter 4, Sections 4.2 "Drive Frequency Command Generator," 4.3 "Drive
Command Generator" and 4.4 "Internal Command Decoders," and the user's manual
of RS485 communication for more details.
Reset PID integral and differential components--(PID-RST)
(Function code data = 33)
Turning ON the (PID-RST) command resets the PID integral and differential components.
Hold PID integral component--(PID-HLD)
(Function code data = 34)
Turning ON the (PID-HLD) command holds the current inverter output voltage constant by
suppressing an increase of PID integral component.
Run forward--(FWD)
(Function code E98/E99 data = 98)
If the (FWD) command is turned ON, the inverter runs the motor forward; if OFF, it
decelerates the motor to a stop.
Run reverse--(REV)
(Function code E98/E99 data = 99)
If the (REV) is turned ON, the inverter runs the motor in reverse; if OFF, it decelerates the
motor to a stop.
E10
Acceleration Time 2
Refer to F07.
E11
Deceleration Time 2
Refer to F08.
Refer to the descriptions of function codes F07 and F08.
Summary of Contents for frenic mini series
Page 1: ...USER S MANUAL Fuji Electric Co Ltd MEH446...
Page 2: ...Compact Inverter User s Manual...
Page 62: ...4 4 4 3 Drive Command Generator Figure 4 2 Drive Command Generator...
Page 66: ...4 8 Figure 4 3 d Terminal Command Decoder ORing with Link Commands Ignoring Link Commands...
Page 68: ...4 10 4 5 Digital Output Selector Figure 4 4 Digital Output Signal Selector...
Page 70: ...4 12 4 6 Analog Output FMA Selector Figure 4 5 Analog Output FMA Selector...
Page 74: ...4 16 4 8 PID Frequency Command Generator Figure 4 7 PID Frequency Command Generator...
Page 81: ...Part 3 Peripheral Equipment and Options Chapter 6 SELECTING PERIPHERAL EQUIPMENT...
Page 124: ...Part 5 Specifications Chapter 8 SPECIFICATIONS Chapter 9 FUNCTION CODES...
Page 134: ...8 3 Common Specifications 8 9 Chap 8 SPECIFICATIONS 8 3 Common Specifications...
Page 135: ...8 10...
Page 257: ...App H Replacement Information A 33 App FVR C11S vs FRENIC Mini...
Page 261: ...Glossary This glossary explains the technical terms that are frequently used in this manual...