Settings – IO mapping
General
This menu item allows you to configure the properties of the inverter's individual
inputs and outputs (I/O). You can only select those settings that are supported
by the system concerned (which are determined by the functionality of the sys-
tem and how it has been configured).
An active output that has not been assigned (is "free") remains active until the in-
verter is restarted. The status of an output only changes in the event of new spe-
cifications for assigned services.
Emergency
power
Function
Description
De-
fault
pin
Grant emergency power locking
Output, triggers disconnection
from the mains (protection)
0
Feedback locking (optional)
Input, gives feedback on whether
locking is active
5
Emergency power request
Input, triggers emergency power
mode
4
Emergency power mode is enabled by configuring these parameters.
Load manage-
ment
Up to four pins can be selected for load management here. Additional load man-
agement settings are available in the "Load management" menu item.
Default pin: 1
IO control
The pins for the IO control can be set here. Additional settings can be adjusted in
the "PSC editor - IO control" menu.
IO control
De-
fault
pin
IO control
De-
fault
pin
IO control 1 (optional)
2
IO control 6 (optional)
7
IO control 2 (optional)
3
IO control 7 (optional)
8
IO control 3 (optional)
4
IO control 8 (optional)
9
IO control 4 (optional)
5
IO control feedback
(optional)
0
IO control 5 (optional)
6
AUS - Demand
Response Modes
(DRM)
Demand Response Modes for Australia
The pins for control via DRM can be set here:
96
Summary of Contents for Energy Package
Page 2: ......
Page 10: ...10...
Page 11: ...General information 11...
Page 12: ...12...
Page 37: ...Operation 37...
Page 38: ...38...
Page 69: ...Fronius system monitoring 69...
Page 70: ...70...
Page 82: ...82...
Page 83: ...Current data services and settings offered by Fronius system monitor ing 83...
Page 84: ...84...
Page 121: ...Troubleshooting and maintenance 121...
Page 122: ...122...
Page 136: ...136...
Page 137: ...Appendix 137...
Page 138: ...138...
Page 145: ...145 EN...
Page 146: ...146...
Page 147: ...147 EN...
Page 148: ......