Code
Description
Behaviour
Remedy
458
Error when recording measuring
signal
The inverter is not feed-
ing any energy into the
grid.
*)
459
Error when recording the measur-
ing signal for the insulation test
460
Reference voltage source for the di-
gital signal processor (DSP) is work-
ing out of tolerance
461
DSP data memory error
462
Error during DC feed monitoring
routine
463
Reversed AC polarity, AC connect-
or inserted incorrectly
474
RCMU sensor faulty
The inverter is not feed-
ing any energy into the
grid.
**)
475
Insulation fault (connection
between solar module and ground)
476
Driver supply voltage too low
480,
481
Functional incompatibility (one or
more PC boards in the inverter are
not compatible with each other, e.g.
after a PC board has been re-
placed)
The inverter is not feed-
ing any energy into the
grid.
Update inverter firm-
ware; *)
482
Setup interrupted after initial start-
up
The inverter is not feed-
ing any energy into the
grid.
Perform AC reset
(switch automatic
circuit breaker off
and on again); up-
date inverter firm-
ware; *)
484 -
489
CAN transmit buffer is full
The inverter is not feed-
ing any energy into the
grid.
Perform AC reset
(switch automatic
circuit breaker off
and on again); up-
date inverter firm-
ware; *)
*) If the status code is displayed all the time: Notify a Fronius-trained service en-
gineer.
**) If this status code keeps recurring, contact your system engineer.
Status codes –
Class 5
Class 5 status codes do not generally interfere with feeding energy into the grid,
but can cause restrictions. These status codes are displayed until they are ac-
knowledged by pressing a key (however, the inverter continues to operate nor-
mally in the background).
Code
Description
Behaviour
Remedy
502
Insulation fault on solar
modules or on the battery
Warning message is
shown on the display
**)
127
EN
Summary of Contents for Energy Package
Page 2: ......
Page 10: ...10...
Page 11: ...General information 11...
Page 12: ...12...
Page 37: ...Operation 37...
Page 38: ...38...
Page 69: ...Fronius system monitoring 69...
Page 70: ...70...
Page 82: ...82...
Page 83: ...Current data services and settings offered by Fronius system monitor ing 83...
Page 84: ...84...
Page 121: ...Troubleshooting and maintenance 121...
Page 122: ...122...
Page 136: ...136...
Page 137: ...Appendix 137...
Page 138: ...138...
Page 145: ...145 EN...
Page 146: ...146...
Page 147: ...147 EN...
Page 148: ......