Defined discharge
3000 W
PV power
1000 W
In this case, the inverter would need to reduce the PV power to 0 W, as the out-
put power of the Fronius Symo Hybrid 3.0-S is max. 3,000 W and the device is
already fully utilised through the discharging.
Since it does not make sense to waste PV power, the power limitation for the bat-
tery control parameters is automatically adjusted so that no PV power is wasted.
In the above example, this means that the battery is only discharged with 2,000
W, so that the 1,000 W of PV power can be used.