Fronius Solar Battery
Status code dis-
play
The storage system performs a system self-diagnosis that automatically detects
many faults that may occur. These are indicated on the display or via LEDs. This
means you are promptly made aware of malfunctions in the storage system, or of
any installation or operating faults.
If the system self-diagnosis has detected a specific fault, the associated status
code will be shown on the display.
Error messages
– Battery man-
agement module
Indicator
Details
Solution
NO MODULE
No module
Connect modules
If modules are connected
The message on the left
appears even if modules
are connected. Check
whether they have been
connected properly.
OV Error
Overvoltage
Discharge
DISCHARGE
ERR
Deep discharge
Charge
COMM ERR
or CON=
-------------
ooox
Error affecting communication
with connected modules. The ex-
ample on the left illustrates a
scenario in which one module
(no. 00) is affected by a commu-
nication error, 3 modules (nos.
01, 02 and 03) are connected
and the other addresses are
without a connection.
COMM OFF
MODE
For maintenance only
No informa-
tion displayed
Wiring error, storage module ad-
dressing error or system-critical
error
Check wiring, check ad-
dress settings for individu-
al storage modules
Error message –
Data converter
If the data converter detects an error, the “State” LED lights up steady red to
signal that an error has occurred. At the same time, the associated error mes-
sages are displayed via the “Error No” LEDs in accordance with table below.
There are two different error categories:
Serious errors (1 - 5): In this case, the data converter has to be switched off and
then back on again. If the error recurs, the data converter must be replaced and
sent away for repair.
Warnings (6 - 15): These warnings are displayed for information only. They appear
for 1 minute and are then reset automatically. If these warnings occur quite fre-
quently, Customer Services should be notified accordingly.
These displays are not applicable in Configuration mode and are intended for in-
ternal purposes only.
133
EN
Summary of Contents for Energy Package
Page 2: ......
Page 10: ...10...
Page 11: ...General information 11...
Page 12: ...12...
Page 37: ...Operation 37...
Page 38: ...38...
Page 69: ...Fronius system monitoring 69...
Page 70: ...70...
Page 82: ...82...
Page 83: ...Current data services and settings offered by Fronius system monitor ing 83...
Page 84: ...84...
Page 121: ...Troubleshooting and maintenance 121...
Page 122: ...122...
Page 136: ...136...
Page 137: ...Appendix 137...
Page 138: ...138...
Page 145: ...145 EN...
Page 146: ...146...
Page 147: ...147 EN...
Page 148: ......