LED8
LED4
LED2
LED1
Error no.
or ID
Display
0
0
0
0
0
Reserved
0
0
0
1
1
Hardware fault
0
0
1
0
2
EEROM fault
0
0
1
1
3
Internal memory error
0
1
0
0
4
Fieldbus hardware fault
0
1
0
1
5
Script error
0
1
1
0
6
Reserved
0
1
1
1
7
RS transmission buffer overflow
1
0
0
0
8
RS receiver buffer overflow
1
0
0
1
9
RS timeout
1
0
1
0
10
General fieldbus error
1
0
1
1
11
Parity error or stop bit error
(frame check)
1
1
0
0
12
Reserved
1
1
0
1
13
Fieldbus configuration error
1
1
1
0
14
Fieldbus data buffer overflow
1
1
1
1
15
Reserved
Undefined oper-
ating statuses
Battery switches off during start-up procedure:
Keep the battery switched off for at least 120 minutes and then switch it on
again. If this does not resolve the error, notify Customer Services.
Battery switched off with a SOC (state of charge) of 0%:
Communication error – Disconnect the inverter on the DC side and isolate it
from the grid on the AC side. Wait 5 minutes and then reconnect the inverter on
both the DC and AC sides. If this does not resolve the error, notify Customer
Services.
Battery active, state of charge (SOC) is more than 90% and red LED is flashing:
Battery charging error – Disconnect the inverter on the DC side and isolate it
from the grid on the AC side. Wait 30 minutes and then reconnect the inverter
on both the DC and AC sides. If this does not resolve the error, notify Customer
Services.
Battery not charging or discharging (SOC indicated on web interface does not
match that of the battery):
Check whether battery is switched on – If it is not, switch it on.
If it is, there is a communication error – Disconnect the inverter on the DC side
and isolate it from the grid on the AC side. Wait 5 minutes and then reconnect
the inverter on both the DC and AC sides. If this does not resolve the error, noti-
fy Customer Services.
Battery no longer being displayed on web interface (triangular view instead of
square view):
Check whether battery is switched on – If it is not, switch it on.
If it is, there is a communication error – Disconnect the inverter on the DC side
and isolate it from the grid on the AC side. Wait 5 minutes and then reconnect
134
Summary of Contents for Energy Package
Page 2: ......
Page 10: ...10...
Page 11: ...General information 11...
Page 12: ...12...
Page 37: ...Operation 37...
Page 38: ...38...
Page 69: ...Fronius system monitoring 69...
Page 70: ...70...
Page 82: ...82...
Page 83: ...Current data services and settings offered by Fronius system monitor ing 83...
Page 84: ...84...
Page 121: ...Troubleshooting and maintenance 121...
Page 122: ...122...
Page 136: ...136...
Page 137: ...Appendix 137...
Page 138: ...138...
Page 145: ...145 EN...
Page 146: ...146...
Page 147: ...147 EN...
Page 148: ......