MPP Tracker 1
-
DC operating mode: MPP AUTO / FIX / MPP USER
-
MPP AUTO: normal operating status; the inverter automatically
searches for the ideal operating point
-
FIX: for entering a fixed DC voltage at which the inverter will operate
-
MPP USER: for entering a lower MP voltage above which the inverter
will search for its ideal operating point
-
Dynamic Peak Manager: ON / OFF
-
Fixed voltage: for entering a fixed voltage (150 - 800 V)
-
MPPT start voltage: for entering the start voltage (150 - 800 V)
Input signal
-
Function of the: Ext Sig. / S0-Meter / OFF
Only with the Ext Sig.: function selected:
-
Triggering method: Warning (warning shown on display) / Ext. Stop
(inverter switches off)
-
Connection type: N/C (normally closed contact) / N/O (normally open
contact)
SMS / relay
-
Event delay:
for entering the time delay after which an SMS is sent or the relay is to
switch
900 - 86,400 seconds
-
Event counter:
for entering the number of events that lead to signalling:
10 - 255
Insulation setting
-
Insulation warning: ON / OFF
-
Threshold warning: for entering a threshold that leads to a warning
-
Threshold fault: for entering a threshold that leads to a fault (not avail-
able in all countries)
-
Both the PV system and the battery are monitored
Temperature warning
For activating/deactivating the overtemperature warning for each event
ON / OFF
TOTAL Reset
Under the LOG menu item, this setting resets the max. and min. voltage values
and the max. power of feeding in to zero.
Once the values have been reset, this action cannot be undone.
To reset the values to zero, press the "Enter" key.
"CONFIRM" is displayed.
Press "Enter" again.
The values are reset and the menu is displayed
68
Summary of Contents for Energy Package
Page 2: ......
Page 10: ...10...
Page 11: ...General information 11...
Page 12: ...12...
Page 37: ...Operation 37...
Page 38: ...38...
Page 69: ...Fronius system monitoring 69...
Page 70: ...70...
Page 82: ...82...
Page 83: ...Current data services and settings offered by Fronius system monitor ing 83...
Page 84: ...84...
Page 121: ...Troubleshooting and maintenance 121...
Page 122: ...122...
Page 136: ...136...
Page 137: ...Appendix 137...
Page 138: ...138...
Page 145: ...145 EN...
Page 146: ...146...
Page 147: ...147 EN...
Page 148: ......