Code
Description
Behaviour
Remedy
976
Unregistered battery mod-
ule detected
Battery operation not
possible, feed-in re-
sumes
Enter activation key for bat-
tery module; *)
977
Incorrect number of bat-
tery modules connected to
Fronius Solar Battery
Too many modules de-
tected: Battery opera-
tion not possible
Too few modules detec-
ted: Error message out-
put, operation resumes
978
Communication error
between Fronius Symo Hy-
brid and Fronius Solar Bat-
tery
Battery operation not
possible, feed-in re-
sumes
Check wiring; **)
979
Communication error
between Fronius Symo Hy-
brid and Fronius Solar Bat-
tery
Battery operation not
possible, feed-in re-
sumes
Displayed in standby mode, if
not in standby mode - check
wiring; **)
980
No communication
between Fronius Symo Hy-
brid and Fronius Solar Bat-
tery
Battery operation not
possible, feed-in re-
sumes
Switch on Fronius Solar Bat-
tery; check wiring; **)
981
Software version of Froni-
us Solar Battery is incon-
sistent
Battery operation not
possible, feed-in re-
sumes
*)
983
Communication error
between battery controller
and battery modules
Battery operation not
possible, feed-in re-
sumes
Check wiring in Fronius Solar
Battery; check numbers of
individual battery modules;
check termination plug
984
Battery controller has
stopped Charge mode
Battery operation not
possible, feed-in re-
sumes
Check error message on
Fronius Solar Battery dis-
play; *)
985
Undervoltage at Fronius
Solar Battery
Fronius Solar Battery
has tripped due to un-
dervoltage. Battery op-
eration not possible,
feed-in resumes
*)
986
Overtemperature at Froni-
us Solar Battery
Fronius Solar Battery
has tripped due to over-
temperature. Battery
operation not possible,
feed-in resumes
Reduce ambient temperat-
ure; switch off Fronius Solar
Battery and activate it again
after waiting an appropriate
amount of time; *)
987
Undertemperature at
Fronius Solar Battery
Fronius Solar Battery
has tripped due to un-
dertemperature. Battery
operation not possible,
feed-in resumes
Increase ambient temperat-
ure; switch off Fronius Solar
Battery and activate it again
after waiting an appropriate
amount of time; *)
988
Communication error
between Fronius Symo Hy-
brid and Fronius Smart
Meter
No meter data available
Battery operation not
possible, feed-in re-
sumes
Check wiring; **)
131
EN
Summary of Contents for Energy Package
Page 2: ......
Page 10: ...10...
Page 11: ...General information 11...
Page 12: ...12...
Page 37: ...Operation 37...
Page 38: ...38...
Page 69: ...Fronius system monitoring 69...
Page 70: ...70...
Page 82: ...82...
Page 83: ...Current data services and settings offered by Fronius system monitor ing 83...
Page 84: ...84...
Page 121: ...Troubleshooting and maintenance 121...
Page 122: ...122...
Page 136: ...136...
Page 137: ...Appendix 137...
Page 138: ...138...
Page 145: ...145 EN...
Page 146: ...146...
Page 147: ...147 EN...
Page 148: ......