Operating Manual BKS600A
6
4.3
Electronic Control Unit
Common
The electronic unit is mounted to a robust aluminium housing. It contains the power amplifier
to drive the actuator and the power amplifiers to drive the linear units. The electronic unit has
no trimmers and only few jumpers to keep most accurate long-time and temperature stability.
Operation
The large backlit display with 2x16 characters, 4 LED’s and large keys guarantee simple
operation. All information is in plain text with the following languages selectable: English,
German, French and Italian. Most of the functions may be paramterized. The parametrization
can be done via the keys or the interfaces. All inputs are fail-safe stored in an EEPROM.
Additional settings can be made with jumpers or solder bridges.
Interface
As an option, there are RS232, PROFIBUS, CAN-Bus or DeviceNet interfaces available. All
inputs and settings can be made by the integrated operation panel or by the interfaces.
fig. 2: Block diagram BKS600A
K600024e