Operating Manual BKS600A
27
9.2
List of the System Parameters
Parameter
Unit
Min
Max
Default
Selected
Language
English, French, Italian, German
Measuring System
Metric, US standard
Metric
Lowpass
display
[Hz]
0.1 10.0 1.0
Identifier
[-]
0 255 0
Baud rate
2400, 4800, 9600, 19200
9600
9.3
List of the Parameters BKS600A
Parameter
Unit
Min
Max
Default
Selected
Control mode
Edge left, Edge right, Center
Dead
band
[mm]
0.0 5.0 0.0
Device active
Yes, No
Yes
Analog output
Feedback sensor, Controller out
Feedb.sens.
Scale
feedback
[mm]
0.1 3200.0 5.0
Output manual
[%]
–100.0
100.0
5.0
Offset output
[Digit]
–200
200
0
Limit output
[%]
10.0
100.0
100.0
P value output
[-]
0.01
320.00
1.00
I value output
[s]
0.01
320.00
1.00
Output config.
0...10V and 0...20mA, 0...10V and 4...20mA, ±10V
Output direction
Standard, Inverted
Standard
Base distance left
[mm]
0.0
3200.0
0.0
Base distance right
[mm]
0.0
3200.0
0.0
Digital input 1
Automatic, Center pos, Reference –,
Ref,Manual left, Manual right, Start
detection, Sensor freerun
Automatic
Digital input 2
(same as digital input 1)
Center
pos
Digital input 3
(same as digital input 1)
Reference
–
Digital input 4
(same as digital input 1)
Reference
+
Digital output 1
Automatic ok, Edge missing,
Detection ok
Auto ok
Digital output 2
(same as digital output 1)
Edge
miss.