8.2
Configuring the Electronic Unit
Prior to the first calibration, the following settings must be done (ref. to „9. Parametrization“
and „14. Technical reference“):
System parameters
Language
Required display language
Service parameters
Motor config.
1)
Standard
Stroke motor
1)
depending on steering device used
Start pos. motor
1)
(will be set with Line-up of the limit positions;
Center pos. motor
1)
ref. to „9.7 Line-up of the limit positions and Offset
End pos. motor
1)
compensation“)
Offset motor
1)
determine with Offset compensation; ref. to „9.7 Line-up of
the limit positions and Offset compensation“
Length of rail left
(only if left rail is used)
Length of rail right
(only if right rail is used)
Sensor covered
depending on sensor used
Sensor uncovered
depending on sensor used
Sensor range
depending on sensor used
1)
only if no steering frame is used
Parameters BKS600A
Control mode
According to requirements
Dead band
For the time being set to 0mm
Analog output
2)
Controller output
2)
or
Feedback sensor
Scale feedback
2)
According to requirements
Output manual
2)
According to requirements
Offset output
2)
For the time being set to 0
Limit output
2)
For the time being set to 100%
Output config.
2)
According to requirements
Output direction
2)
Standard
Base distance left
For the time being set to 0mm
Base distande right
For the time being set to 0mm
2)
only if analog controller output is used
Note
Wrong setting of the parameters may cause malfunction of the electronic unit! Setting of the
parameters must be done carefully prior to setting into operation!