Operating Manual BKS600A
35
End pos. motor
Use:
Value of the position feedback potentiometer when the steering frame is in the
second end position. Value determined with special function
Init. Motor
.
Range:
0
to
8191
Default:
1700
Increment:
1
Unit:
[-]
Reference auto.
Use:
This parameter defines which position will be taken by the steering frame
during automatic start.
Range:
Center of sensor, Feedback sensor
Default:
Center
Length of rail left
Use:
This parameter defines the length of stroke of the left linear unit. This
value is required to determine the limit position on the side opposite to the
limit switch.
Range:
100.0
to
1300.0
Default:
200.0
Increment:
0.1
Unit:
[mm]
Length of rail right
Use:
This parameter defines the length of stroke of the right linear unit. This
value is required to determine the limit position on the side opposite to the
limit switch.
Range:
100.0
to
1300.0
Default:
200.0
Increment:
0.1
Unit:
[mm]
Pitch of rail
Use:
This parameter stores the spindle pitch of the linear units. The value is used
to calculate the current position of the sensors. The parameter is used for
both left and right linear units.
Range:
5.0
to
20.0
Default:
5.0
Increment:
0.1
Unit:
[mm]
Rail auto-follow
Use:
This parameter allows to set if the sensors should follow the web edge
automatically during center guide automatic mode. If the parameter is set
to
On
and the web edge is more than ±2mm out of the sensor center, the
sensors are moved and the sensor center is readjusted to the web edge.
Range:
Off,
On
Default:
Off