Operating Manual BKS600A
16
7.5
Mounting of the Linear Units
The linear units must be installed
after
the steering frame regarding running direction (fig. 13).
They will be mounted directly to the machine frame using the supplied brackets.
Wiring of the linear units is done according to wiring diagram (fig. 10). The electronic control
unit detects automatically if 1 or 2 linear units are connected.
Note
For optimum control results, the linear units have to be placed in a way that the sensors are
placed next to the exit roller of the steering frame. If the sensors are placed far from the
steering frame, control dynamics will be reduced drastically.
Caution
If external parts are in the travel range of the linear units, the sensors can be damaged while
moving! It is to ensure that large enough distances are kept allover.