Mounting of the Edge Sensors
The edge sensors will be mounted by brackets to the sensor adjustment (refer to operating
manual AZS01 and US01). The sensors may be mounted to the left or right web edge.
fig. 14: Position of the edge sensors referring to the web. They may be mounted to the
left-hand or right-hand side.
K400005e
Wiring of the edge sensors to the terminals is done according to wiring diagram (fig. 9).
The FMS sensors provide a signal of 0...10V. If sensors with different signal range are used,
this must be parametrized (refer to „8.2 Configuring the Electronic Unit“).
Note
The inputs for the analog signals have different Gnd terminals. Therefore the terminals
Gnd
and
Signal Gnd
have to be bridged. If not, malfunction may appear.