• Push the cable through cap nut, compression part, basic part and sealing ring (sealing ring: only for cable gland M20, not
for cable gland 1/2 NPS).
• Insert the cable into the housing of the transmitter.
• Push the cable through the ferrite nut.
• Prepare the cable. For the preparation of the cable, see the supplied manufacturer's documents.
• Mount the connector. For the mounting of the connector, see the delivered manufacturer's documents.
• Insert the connector into the Ethernet port.
• Position the cable in the housing as shown in Fig. 7.14.
• Fix the cable gland by screwing the cap nut onto the basic part.
• Fix the transducer cable by tightening the cable gland with the ferrite nut, see Fig. 7.14.
Transmitter with aluminum housing
• Remove the blind plug on the transmitter to connect the cable, see Fig. 7.16.
• Open the cable gland of the Ethernet cable. The compression part remains in the cap nut, see Fig. 7.17.
Fig. 7.15:
Cable gland
1 – cap nut
2 – compression part
3 – basic part
4 – sealing ring (only for cable gland M20, not for cable gland 1/2 NPS)
5 – housing wall
6 – ferrite nut
Fig. 7.16:
Connection of the Ethernet cable (transmitter with aluminum housing)
1 – Ethernet interface
2 – foldable ferrite core
3 – Ethernet connector
2
1
3 4
5
6
2
1
3
Summary of Contents for FLUXUS WD
Page 1: ...FLUXUS WD UMFLUXUS_WDV1 3EN Operating instruction...
Page 6: ...Table of contents FLUXUS WD 2018 07 16 UMFLUXUS_WDV1 3EN 6...
Page 150: ...18 Settings 18 9 Key lock FLUXUS WD 2018 07 16 UMFLUXUS_WDV1 3EN 150...
Page 172: ...Annex D Conformity declarations FLUXUS WD 2018 07 16 UMFLUXUS_WDV1 3EN 172...
Page 173: ......
Page 174: ......