7 Connection
UMFLUXUS_F7V4-6-2EN, 2017-10-01
65
• Fix the cable gland by screwing the cap nut onto the basic part.
• Connect the transducer cable to the terminals of the junction box (see Fig. 7.20 or Fig. 7.21 and Tab. 7.9).
Tab. 7.9: Terminal assignment (KL1)
terminal (JBP2, JBP3)
terminal (JB01)
connection
TV
V
transducer
(core)
TVS
VS
transducer
(shield)
TRS
RS
transducer
(shield)
TR
R
transducer
(core)
Fig. 7.18: Cable gland
Fig. 7.19: Connection of the transducer cable
with plastic cable jacket and stripped cable ends
Fig. 7.20: Terminal designation (junction box JBP2, JBP3)
Fig. 7.21: Terminal designation (junction box JB01)
cap nut
compression part
basic part
100
mm
20
m
m
10
m
m
TV
TV
S
TG
TG
TR
S
TR
K L 2
K L 1
TV
TV
S
TR
S
TR
external shield,
brushed back
TV
TV
S
TG
TG
TR
S
TR
TV
TV
S
TR
S
TR
K L 2
K L 1
TV
TV
S
TG
TG
TR
S
TR
V
V
S
R
S
R
K L 2
K L 1