A Menu Structure
UMFLUXUS_F7V4-6-2EN, 2017-10-01
167
selection of the range of the sound speed
auto
: The area around the average sound speed is defined by the transmitter.
user
: The area around the average sound speed has to be entered.
input of the range around the average sound speed of the medium
This display will only be indicated if
Other Medium
has been selected.
input of the kinematic viscosity of the medium
range: 0.01...30 000 mm²/s
This display will only be indicated if
Other Medium
has been selected or no
data set for the selected medium is stored in the transmitter.
input of the operating density of the medium
range: 0.01...20 g/cm³
This display will only be indicated if
Other Medium
has been selected.
input of the medium temperature
default: 20 °C
input of the medium pressure
range: 1...600 bar
This display will only be indicated if
Special Funct.\SYSTEM set-
tings\Dialogs/Menus\ Fluid pressure
is activated.
selection of the transducer type
This display will only be indicated if no or special transducers are connected.
input of the length of an extension cable
When a Calculation Channel is Selected (Y, Z)
Calculation channels will only be available if the transmitter has more than one measuring channel.
display of the current calculation function
selection of the calculation function
Program Branch
Measuring
main menu: selection of the program branch
Measuring
activation of the channels
This display will not be indicated if the transmitter has only one measuring chan-
nel.
input of the measuring point number
This display will only be indicated if
Output Options\Store Meas.Data
and/or
Serial Output
are activated.
activation/deactivation of the flow profile correction
This display will only be indicated if
Special Funct.\SYSTEM settings\
Measuring\Flow Velocity
=
uncorr.
has been selected.
INIT-
resistant
c-Medium range
auto
>USER<
c-Medium=1500m/s
range +-150m/s
Kinem.Viscosity
1.00
mm2/s
Density
1.00
g/cm3
Medium Temperat.
20.0
C
Fluid pressure
1.00
bar
Transducer Type
↕
Standard
Additional cable
65.0
m
Calculation:
Y= A - B
>CH1< funct ch2
↕
A - B
par >MEA< opt sf
Measuring
CHANN: >A< B Y Z
MEASUR
- .
A:Meas.Point No.:
xxx (
↑↓←
→
)
A:PROFILE CORR.
>NO<
yes