6 Installation
UMFLUXUS_F7V4-6-2EN, 2017-10-01
41
6.4.4.2
Installation of the Rail
Select the installation instructions that correspond to the supplied clasp:
• see section Installation of the rail without a clasp
• see section Installation of the rail with the ratchet clasp
Installation of the rail without a clasp
• Cut the tension strap to length (pipe circumf at least 120 mm).
• Insert approx. 100 mm of the tension strap into one of the slots of the tension strap clamp and bend it (see Fig. 6.42).
• If necessary, insert the long end of the tension strap into the metal spring (see Fig. 6.43). It is not necessary to mount the
metal spring:
– on steel pipes
– on pipes with an outer pipe diameter < 80 mm or
– on pipes that are not subjected to significant temperature fluctuations
• Place the tension strap around the pipe (see Fig. 6.44).
• Position the metal spring (if mounted) and the tension strap clamp (see Fig. 6.44):
– On a horizontal pipe, mount the tension strap clamp on the side of the pipe, if possible.
– Mount the metal spring (if necessary) on the opposite side of the tension strap clamp.
Fig. 6.41: Disassembly of Variofix C
Note!
The edge of the tension strap is very sharp, leading to risk of injury. Remove the burr of the sharp
edge.
Fig. 6.42: Tension strap with tension strap clamp
Fig. 6.43: Tension strap with the metal spring and the tension strap clamp
cover
rail
spring clip
tensioning screw
spacing element
tension strap clamp
indentation
tension strap clamp
tension strap clamp
metal spring
metal spring