6 Installation
36
UMFLUXUS_F7V4-6-2EN, 2017-10-01
6.4.3.4
Fixing the Rail to the Pipe
• Place one tension strap clamp in the rail (see tension strap clamp 1 in Fig. 6.25). Observe the orientation of the tension
strap clamp.
• Tighten the nut of tension strap clamp 1 slightly.
• Screw the rail to tension strap clamp 2 (see Fig. 6.26).
• Tighten the nut of tension strap clamp 2, but not too firmly in order not to damage the tension strap.
• Select the installation instructions that correspond to the supplied clasp:
Band Clamp Clasp
• Insert the tension strap into tension strap clamp 1 (see Fig. 6.27).
• Place the tension strap around the pipe and insert it into the clasp (see Fig. 6.28).
• Tighten the tension strap.
• Tighten the screw of the clasp.
• Tighten the nut of tension strap clamp 1, but not too firmly in order not to damage the tension strap (see Fig. 6.27).
Fig. 6.25: Rail with tension strap clamp
Fig. 6.26: Rail, mounted on one side of the pipe
Fig. 6.27: Rail on the pipe
Observe the
orientation!
nut
tension strap 1
nut
tension strap 2
tension strap 2
tension strap 1
nut
clasp
metal spring
tension
strap 1