7 Connection
UMFLUXUS_F7V4-6-2EN, 2017-10-01
57
7.1.1.3
Transducer Cable with Stainless Steel Conduit and Stripped Cable Ends
• Remove the left blind plug for the connection of the transducer cable (see Fig. 7.9 or Fig. 7.10).
FLUXUS F704
• Insert the transducer cable into the housing.
• Fix the transducer cable by tightening the cable gland.
• Connect the transducer cable to the terminals of the transmitter (see Fig. 7.1, Fig. 7.9 and Tab. 7.3).
FLUXUS F705, F706
• Push the transducer cable through the sealing ring (only for cable gland M20, not for cable gland 1/2 NPS).
• Insert the transducer cable into the housing.
• Fix the transducer cable by tightening the cable gland with the counter nut.
• Connect the transducer cable to the terminals of the transmitter (see Fig. 7.2, Fig. 7.10 and Tab. 7.3).
Attention!
Observe the "Safety Instructions for the Use in Explosive Atmosphere" (see document SIFLUXUS).
Tab. 7.3: Terminal assignment (transducer cable)
terminal
connection
AV
transducer (white cable, marked white)
AVS
transducer (red cable)
ARS
transducer (red cable)
AR
transducer
(white
cable)
Fig. 7.9: Connection of the transducer cable with stainless steel conduit
and stripped cable ends to the transmitter FLUXUS F704
AVS
AV
AGN ARS AR
BVS
BV
BGN BRS BR
SA1 SA2 SA3 SA4
SB1 SB2 SB3 SB4
T1a T1b S2 T2a
T3a T3b S4 T4a
T2b
T4b
T1A T1B S1 T2A
T3A T3B S3 T4A
T2B
T4B
A+ B- P1+ P2+
P4+ P5a P6a P7a
P3+
101 103 P1- P2-
P4- P5b P6b P7b
P3-
PE N(-) L(+)
transducers
measuring channel B
transducers
measuring channel A
equipotential bonding terminal
(FLUXUS F704**-A2)