Terms and abbreviations
404
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
Term/abbreviation
Significance
Integrated Drive
Includes power electronics, regulator, positioning controller, motor
and motor encoder (optional). Evaluates sensor signals and calcu
lates movements and forces.
Jog mode
Manual travel in a positive or negative direction.
Function for setting positions by approaching the target position,
e.g. when teaching position sets (Teach mode).
Load voltage, logic voltage
The load voltage supplies the power electronics of the EMCA and
thereby the motor. The logic voltage supplies the evaluation and
control logic of the EMCA.
Logic 1
Means that there is a 24 V signal present at the input or output (pos
itive logic, corresponds to HIGH).
Operating mode
Type of control or internal operating mode of the EMCA.
–
Type of control: record selection mode, direct operation
–
Operating mode of the controller: position profile mode,
profile torque mode, profile velocity mode
–
Predefined sequences: homing mode...
Positioning mode
(Profile Position mode)
Operating mode for executing a position set or a direct positioning
task with position control (closed loop position control).
Project zero point (PZ)
(Project Zero point)
Point of reference for all positions in positioning tasks. The project
zero point PZ forms the basis for all absolute position specifications
(e.g. in the position set table or with direct control via control inter
face). The PZ is defined by an adjustable distance (offset) from the
axis zero point.
Record
Travel command defined in the record table, comprising target posi
tion, positioning mode, travel speed and acceleration.
Reference point (REF)
Point of reference for the incremental measuring system. The refer
ence point defines a known orientation or position within the travel
distance of the drive.
Reference switch
External sensor used for ascertaining the reference position and
connected directly to the EMCA.
Referencing mode
(Homing mode)
Definition of the measuring reference system of the axis
Software end position
Programmable stroke limit (point of reference = axis zero point)
–
Software end position, positive/negative:
max. limit position of the stroke in positive/negative direction;
must not be exceeded during positioning.
Summary of Contents for EMCA-EC-67 CO Series
Page 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Page 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Page 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Page 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Page 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Page 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Page 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Page 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Page 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Page 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Page 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Page 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Page 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Page 415: ......